Products
Power Manager (True On Line) UPS series
Power Manager Uninterruptible Power Supplies
PM1500 and PM2000-RM Series
Professional Grade Power UPS for Analytical and Diagnostic Equipment
Overview
SYSTEL's TRUE ON-LINE Uninterruptible Power Supplies Technology with built-in Power Conditioning characteristic was developed in order to overcome the limitations inherent in other power conversion designs currently on the market, protecting sensitive and critical equipment, offering a premium cost effective solution. Common UPSes in the markets are designed for computer loads, taking advantage of the "forgiving" design of their switching power supplies which manage blackouts and brownouts of more than 50 milliseconds without necessarily affecting operation or damaging computer equipment.
However, analytical and diagnostic equipment can be severely affected by even shorter power line disturbances such as voltage sags, spikes, surges, lightning, common mode noise or extensive brownouts.
All common technologies of On-line UPSes, as well as Line Interactive and Off-line UPSes, are based on surge-suppressor filtering technology alone and they do not offer ample protection to line contamination that can be passed on to the protected equipment, at significant levels, affecting operation and possibly damaging the sensitive equipment under back up.
In addition as mentioned before, the common UPSes are designed to address, in particular, the computer load type (also known as electronic load) with a steady state regimen, and not to handle complex and "gulping" loads usually integrated in analytical and diagnostic equipment, like high input current crest factor power supplies, motors, pumps, transformers, valves, heaters, lamps, sensors, etc. The common UPSes request an extra power rate capacity for driving these types of loads. When operating such loads at startups, shutdowns, partial switching and asymmetrical current mode, they can generate even voltage overshoots and continuous DC voltage component, damaging the equipment that they are supposed to protect.
Implementation in unique environments
SYSTELs UPSes provide an excellent solution for the worst of line conditions (extreme voltage and frequency fluctuations), particularly in countries with unstable electrical networks or developing countries undergoing accelerated expansion of their electrical power network. The UPSes also excel in remote, isolated locations backed-up by auxiliary supplies, such as emergency motor generators.
India is an example of a country with poor line conditions: voltage fluctuations are between -30% to +25% according to the daily load on the local electrical network. Systels UPSes have been customized for Indian conditions, are manufactured under license and marketed by Adtech under the name PM 1K-23. In a survey conducted by PC Quest magazine evaluating the cost performance of 22 worldwide UPS manufacturers (APC, Exide, Fiskars, Victron, etc.) Systels UPS won first place.
We have succeeded in providing high quality together with a cost effective solution for full power protection of a large number of sensitive and costly equipment. A few illustrative examples of this are:
The MRI systems manufactured by Philips Medical Systems with our PM 1500 series.
Philips Medical Systems is marketing this equipment worldwide, especially in zones with unstable electrical power. In their case, our UPSes satisfactorily protect the computer and electronic loads split from the coils and other heavy but not vital loads. After checking all kinds of options with at least 3 KVA Power Rating, our system was chosen by the client because of its capability, amongst other things, to drive non-linear loads without derating its power conditioner behavior, and its capability to work from the worst power supply sources, including motor generator.
Regarding applications in sites backed up with emergency power source,
Israeli army applications
Systels UPSes succeeded in meeting the stringent requirements of Israeli army applications where vital equipment is being supplied from motor generators in the field, solving problems that seemed insolvable with the available budget.
Technology
Systel is a pioneer in the R&D of digital control for power conversion products. Since 1984 Systel has been involved in R&D and manufacturing of digital controlled On-line UPSes.
The PM UPS series is based on Systel's patented control technology of power conversion topology, characterized by bi-directional, four-quadrant inverter and a unique multi-feedback, digital-embedded pulse-by-pulse control, using property digital ICs. This technology eliminates the limitations inherent in other power conversion designs currently on the market based on analog controls.

SYSTEL TRUE ON-LINE POWER CONDITIONED UPS
Four Quadrant Power Conversion Topology and
Digital Control Technology Implementation
Mains or emergency generator |
Input rectifier |
High frequency bi-directional chopper |
High frequency ultra isolated with multi shielded array energy storage transformer |
Wave synthesizer 50hz/60hz |
Load |
Systel's power manager software |
| SYSTEL FOUR QUADRANT TECHNOLOGY |
|
40 AMP UNMODIFIED INRUSH CURRENT PULSE (CREST FACTOR ABOVE 4.7) IS MEASURED WHEN THE LOAD IS FED FROM THE LINE |
 |
|
23 AMP PULSE MODIFIED LOAD CURRENT SUPPLIED BY SYSTEL'S UPS |
|
INVERTER OUTPUT VOLTAGE (168V PEAK) ONLY SMALL DISTORTION IS VISIBLE IN THE INRUSH CONDITION |
| DETAILED HALF CYCLE OPERATION |
|
Input Highlights |
Output Highlights |
- No reflection on Input of Output Overloads and Startups
- Works under any frequency deviation w/o Battery discharge
- Broad Input Voltage Range -30%/ +15% (-20% w/o Battery discharge)
- Input overvoltage protected
- Start at full Load without By Pass to line
- Sourced from emergency generator w/o affecting output stability
|
- Ultra Galvanic isolated from Input
- Output grounded (floating optional)
- Support any type or combination of Load: any Crest Factor, Power Factor, Asymmetrical and Laser Load, etc. w/o DC Content, Voltage Overshoots or power derating
- Load Soft Start
- Up to 250% of Short Circuit Current
- Non Crashable Behavior - auto recovering <1ms from shorts
- 40 microseconds Control time response
- Output Frequency selectable to 50 or 60Hz
- Digital Phase Lock Looping to input w/ 3 Sec/Hz Slew Rate
- Supports loads w/ 300% Repetitive Peak Rated Power
|
Product/Item |
Description |
OS |
|
|
UPS PM 1500 specifiction |
All |
 |
|
UPS PM 2000 specifiction |
All |
|
|
Full control & settings over the UPS |
win 95/98/00 |
|
PMW-Power Manager Software |
Full control & settings over the UPS |
win NT4 |
|
|
Full control & settings over the UPS PM 1500VA 230V |
DOS |
|
PMN-Power Manager Software |
provides power monitoring and orderly shut down - UPS PM 1500VA 230V - 7 A/H |
NOVELL
3.11 & later |
|
PMN-Power Manager Software |
provides power monitoring and orderly shut down - UPS PM 1500VA 230V - 11 A/H |
NOVELL
3.11 & later |
|
PMN-USER MANUAL |
|
NOVELL
|
|
|