Systel PLC-Link™ Features and Specifications
PLC-Link is Systel's open protocol for power line carrier communications. In Systel's Energy Saving Lighting System (ESLS), all controllers and ballasts communicate using PLC-Link. Communications by PLC-Link has many advantages for building energy control, including:
- With PLC-Link, there is no need for rewiring control lines when doing building retrofits.
- PLC-Link has a large address space that provides a system level solution (as opposed to protocols such as DALI, which are limited by their address space to providing room-level solutions.)
- PLC-Link supports a DALI command set and is compatible with DALI-based software.
- PLC-Link is virtually error-free.
Systel PLC-Link vs. DALI
Parameter |
DALI Protocol |
Systel's PLC-link™ |
Physical layer |
Two control wires |
Power line carrier |
Requires rewiring in retrofit |
Yes |
No |
Communication method |
Bi phase |
Direct Series Spread Spectrum |
Two way |
Yes |
Yes |
Implementation |
A stand-alone light control system or a “room” level component of a building system |
Floor or wide area network of a BMS or as a stand-alone network for Light control, HVAC, Security, Fire protection and other environmental applications, as well as, for residential network control system for same applications. |
Bandwidth |
N/A |
100 - 200 kHz carrier frequency |
Bit rate |
1200 bit/sec |
2000-4000 bit/sec |
Message length |
16 bits |
32 bits |
Addressable ballasts individually |
64 |
256 |
Addressable zones |
16 |
4096 |
Light scene storage |
16 scenes per controller |
16 scenes per zone |
Broadcast addressing |
Yes |
Yes |
Lighting curve |
Logarithmic |
Can be defined by customer |
RF communication for remote control |
By external add-on |
Inherent in the controller together with the PLC |
Sensors connected to: |
If connected to Main DALI Controller, require long dedicated wiring |
Sensors connected to the nearest Local Control Unit (Wall Control) or to the nearest ballast that comprises Local Control Unit capabilities. This option also saves the installation of the Wall control |
Bi directional protocol |
Yes |
Yes |
Communication Protocol type |
DALI |
PLC-Link™ Systel property - anti-collision type |
Error Code Correction (ERCC) NA |
N/A |
Yes |
Bit Error Rate @ S/N= 6 dB before ERCC |
N/A |
10-10 (for 64 ballast per circuit) |
Erroneous commands probability at S/N = 6 after ERCC |
N/A |
2*10-18 |
Local ID |
8 bits |
11 bits |
Message transmission time |
39.2 msec |
16 msec |
Execution time (search of 32 ballasts) |
10 Sec |
16ms x 32 = 0.5 Sec |
Query capability |
Limited by protocol and ballast design |
Unlimited. All information is available in IDC for transmission |
Lighting Control System configuration |
The ballasts are controlled by Master Unit only. |
All addressable units are able to be controlled by any of the Local Control Units installed at any convenient place and by RF remote control as well. |
Installation Pay Back time (approx.) |
> 5 years |
2 years |